20110105000000093285.jpg

실시간 유전자 증폭장치

상담·문의하기

Real-Time PCR Detection System

  • 모델명 Step One Plus Real Time PCR System
  • 제조사 Applied Biosystems
  • 장비용도 시험
  • 장비구분 화합물전처리/분석장비 > 바이오제조/분석장비 > 유전자증폭장치

상세정보

구축일자 2010-12-10
납품업체 Applied Biosystems
위치 광주광역시 북구 첨단과기로 123 (오룡동) 1 광주과학기술원 금호연구관 F3 308
구성및성능 규격(성능 및 사양) :

* Real Time Analysis can be accomplished on line during the PCR.
* The availability of 12 uniform-temperature wells at each temperature within the gradient enables evaluation and optimization of the maximum number of reaction components and parameters in a single experiment.
* Ultimate range of fluorophore excitation and emission from 450-730nm.
* Up to five different reporter fluorphores can be multiplexed per each sample tube.
* 96 sample tubes are sequentially illuminated by 6 filtered light-emitting diodes(LEDs). All 96 samples are independently excited and detected for each color to minimize cross-talk.
* 5-target multiplex experiments and FRET application were available.
* Sample data can be reanalyzed at any time; raw data files are user accessible.
* It is possible for upgrade CFX384 reaction module.
* Optional Precision Melt Analysis software can import and analyze data files generated from the CFX96 or CFX384 to genotype samples based on the thermal denaturing profiles of double-stranded DNA.
* Up to 4 units can be operated with one PC system simultaneously.
장비안내 * Real Time Analysis can be accomplished on line during the PCR.
* The availability of 12 uniform-temperature wells at each temperature within the gradient enables evaluation and optimization of the maximum number of reaction components and parameters in a single experiment.
* Ultimate range of fluorophore excitation and emission from 450-730nm.
* Up to five different reporter fluorphores can be multiplexed per each sample tube.
* 96 sample tubes are sequentially illuminated by 6 filtered light-emitting diodes(LEDs). All 96 samples are independently excited and detected for each color to minimize cross-talk.
* 5-target multiplex experiments and FRET application were available.
* Sample data can be reanalyzed at any time; raw data files are user accessible.
* It is possible for upgrade CFX384 reaction module.
* Optional Precision Melt Analysis software can import and analyze data files generated from the CFX96 or CFX384 to genotype samples based on the thermal denaturing profiles of double-stranded DNA.