복합발전기 조합별 증분비 곡선 재설정에 관한 연구
A study on the resetting of incremental heat rate curve of combined cycle unit by combination
대한전기학회
최준호
논문정보
- Publisher
- 전기학회논문지
- Issue Date
- 2019-01-15
- Keywords
- -
- Citation
- -
- Source
- -
- Journal Title
- -
- Volume
- 68
- Number
- 1
- Start Page
- 8
- End Page
- 12
- DOI
- ISSN
- 19758359
Abstract
Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all (N:1) combinations of CC.
- 전남대학교