Loading...
2010
전력 손실 평균화 기법에 의한 3상 전압형 인버터의 소손 모드에 관한 연구
A Study of Failure Mode for 3 Phase VSI by Power Loss Averaging Technique
대한전기학회
박성준
논문정보
- Publisher
- 전기학회논문지P
- Issue Date
- 2010-03-15
- Keywords
- -
- Citation
- -
- Source
- -
- Journal Title
- -
- Volume
- 59
- Number
- 3
- Start Page
- 575
- End Page
- 580
- DOI
- ISSN
Abstract
This paper is to design an optimum power conversion device for the system required for development of a low cost 3-phase power inverter. For this purpose, in order to meet with endurance required by the industry, failure mode is standardized to guarantee lifetime of a power semiconductor by monitoring real time power loss and to facilitate failure mode analysis. As normality of heat loss of a power semiconductor is identified remaining in a certain range by comparing heat rise slope between that is calculated by using average current or average loss and that is measured at a heat sink, its feasibility is confirmed by experiment.
- 전남대학교
- KCI
- 전기학회논문지P
저자 정보
| 이름 | 소속 |
|---|---|
| 박성준 | 전기공학과 |