2014
An Analysis of 2D Positional Accuracy of Human Bodies Detection Using the Movement of Mono-UWB Radar An Analysis of 2D Positional Accuracy of Human Bodies Detection Using the Movement of Mono-UWB Radar
한국센서학회
김진영 외 1명
논문정보
Publisher
센서학회지
Issue Date
2014-05-30
Keywords
-
Citation
-
Source
-
Journal Title
-
Volume
23
Number
3
Start Page
149
End Page
157
DOI
ISSN
12255475
Abstract
This paper considers the ability of counting and positioning multi-targets by using a mobile UWB radar device. After a background subtraction process, distinguishing between clutters and human body signals, the position of targets will be computed using weighted Gaussian mixture methods. While computer vision offers many advantages, it has limited performance in poor visibility conditions (e.g., at night, haze, fog or smoke). UWB radar can provide a complementary technology for detecting and tracking humans, particularly in poor visibility or through-wall conditions. As we know, for 2D measurement, one method is the use of at least two receiver antennas. Another method is the use of one mobile radar receiver. This paper tried to investigate the position detection of the stationary human body using the movement of one UWB radar module.

저자 정보

이름 소속
김진영 지능전자컴퓨터공학과