Loading...
2016
Analysis of Time Domain Active Sensing Data from CX-100 Wind Turbine Blade Fatigue Tests for Damage Assessment
Analysis of Time Domain Active Sensing Data from CX-100 Wind Turbine Blade Fatigue Tests for Damage Assessment
한국비파괴검사학회
박규해
논문정보
- Publisher
- 비파괴검사학회지
- Issue Date
- 2016-04-01
- Keywords
- -
- Citation
- -
- Source
- -
- Journal Title
- -
- Volume
- 36
- Number
- 2
- Start Page
- 93
- End Page
- 101
- DOI
- ISSN
- 12257842
Abstract
This paper presents the results obtained using time-series-based methods for structural damage assessment. The methods are applied to a wind turbine blade structure subjected to fatigue loads. A 9m CX-100 (carbon experimental 100kW) blade is harmonically excited at its first natural frequency to introduce a failure mode. Consequently, a through-thickness fatigue crack is visually identified at 8.5million cycles. The time domain data from the piezoelectric active-sensing techniques are measured during the fatigue loadings and used to detect incipient damage. The damage-sensitive features, such as the first four moments and a normality indicator, are extracted from the time domain data. Time series autoregressive models with exogenous inputs are also implemented. These features could efficiently detect a fatigue crack and are less sensitive to operational variations than the other methods.
- 전남대학교
- KCI
- 비파괴검사학회지
저자 정보
| 이름 | 소속 |
|---|---|
| 박규해 | 기계공학부 |