가스터빈 열병합발전소 성능저하 분석에 관한 연구 A Study on Performance Degradation Analysis of Gas Turbine Combined Heat and Power Plant
대한설비공학회
논문정보
Publisher
설비공학 논문집
Issue Date
2016-05-24
Keywords
-
Citation
-
Source
-
Journal Title
-
Volume
28
Number
6
Start Page
248
End Page
255
DOI
ISSN
12296422
Abstract
In this study, the degree of performance changes between the guaranteed performance and the performance after a certain operating start time is calculated by using the performance test of gas turbine CHP. The reason of the performance degradation will then be analysed. For some results of the CHP plant performance tests the comprehensive electric power output was 8,380 kW lower than the guaranteed performance, and the gas turbine’s output was reduced to about 250 kW whenever ambient temperatures rose to 1℃. Also, causes of the performance degradation of gas turbines are ambient temperature rise, temperature aging and air compressor’s efficiency drop.